TAIAN-ECOBAR TECHNOLOGY

TAIAN-ECOBAR TECHNOLOGY was formally called TAIAN Electric Co., Ltd.(TECO GROUP). With the drastic increase in the requirement of safety and stability for power distribution, the traditional power cable and metal-enclosure busway can no longer fulfill the requirement from customers. Therefore, the cast resin insulated busway TECOBAR is the best solution in order to meet the requirement. To provide the safest and most reliable power systems to the world is our commitment. Thus, your precious comments and supports are the most incentive to us.

Company Profile

About Us

2017 TET Launched T-Line Power Distribution Panelboard.
2016 Automation machine of grinding and polishing deployed.
2015 ISO 14001 certification acquired.
2013
  1. ilac-MRA/TAF certification acquired.
  2. Third automation production facility of cast-resin started .
  3. Temperature rise test laboratory and medium voltage test laboratory established.
  4. Factory area extended from 9,000 m2 to 15,000 m2.
2012 TET launched brand TECOBAR.
2011 DEKRA/KEMA type test certification acquired.
2005 Medium Voltage 24kV product line launched into market.
2003 TET became a member of TECO group.
2001 ISO 9001 approved.
2000 Launched low and medium voltage (up to 17.5kV) product.
1999 TET company established.
TAIAN-ECOBAR TECHNOLOGY (TET) was established in 1999 , and began locally producing the cast-resin insulated busway which was invested by an European manufacturer. With continuous concentration and dedication from our team, we are honor to launch a new brand “TECOBAR” into market since 2012. Enhanced electrical and mechanical strength with extraordinary fire retardant and waterproof property and maintenance free, TECOBAR’s highest quality and safety standard has achieved world leading class. TECOBAR aims to bring a clean environment and reliable power for our future. Therefore, continuous innovation and enthusiasm motivates TET to refine TECOBAR to provide a better solution.

Company profile

  • Headquarter : Taipei City, Taiwan
  • Factory Location:Yangmei City, Taoyuan County
  • Production since : 1999
  • Area of manufactory: 15,000 m²
  • Monthly output: more than 10,000 M.
  • Number of Employees:90
Affiliated Partner
  • TECO Group, best known for electric motor

  • Incorporated 1956
  • Revenue: $USD 1.7 billion
  • Total Group of Employees:20,000

Busway Manufacturer

TAIAN-ECOBAR TECHNOLOGY (TET) is a professional manufacturer of Busway and Busduct.  Our main products include Bus Bar, MV Busway, MV Busduct, LV Busway, LV Busduct, etc.  In addition, we also provide Copper Busway, Copper Bus Bar, Copper Busduct, Aluminum Busduct and Aluminum Busway with superior quality and competitive price.  If you are looking for high quality Aluminum Bus Bar, Bus Duct and Bus Bars Manufacturer, please do not hesitate to contact us.

Main Product:

History

2017 TET Launched T-Line Power Distribution Panelboard.
2016 Automation machine of grinding and polishing deployed.
2015 ISO 14001 certification acquired.
2013
  1. ilac-MRA/TAF certification acquired.
  2. Third automation production facility of cast-resin started .
  3. Temperature rise test laboratory and medium voltage test laboratory established.
  4. Factory area extended from 9,000 m2 to 15,000 m2.
2012 TET launched brand TECOBAR.
2011 DEKRA/KEMA type test certification acquired.
2005 Medium Voltage 24kV product line launched into market.
2003 TET became a member of TECO group.
2001 ISO 9001 approved.
2000 Launched low and medium voltage (up to 17.5kV) product.
1999 TET company established.
TAIAN-ECOBAR TECHNOLOGY (TET) was established in 1999 , and began locally producing the cast-resin insulated busway which was invested by an European manufacturer. With continuous concentration and dedication from our team, we are honor to launch a new brand “TECOBAR” into market since 2012. Enhanced electrical and mechanical strength with extraordinary fire retardant and waterproof property and maintenance free, TECOBAR’s highest quality and safety standard has achieved world leading class. TECOBAR aims to bring a clean environment and reliable power for our future. Therefore, continuous innovation and enthusiasm motivates TET to refine TECOBAR to provide a better solution.

Certification

  • ISO 9001:2015
  • Accelerating Aging
  • IP68
  • Seismic Restraint Test
  • Fire Retardant Test
  • IK10
  • Green mark(ROC)
  • China 3C Certification
  • Dekra
  • KEMA
  • ISO 14001:2015
  • Green Mark-LA
  • Green Mark-LB

Company Map

Company Video

History Of Busduct

Low Voltage
  1. Type: LA-LB series
  2. Rated Voltage: < 1000V
  3. Rated Current : 400 to 6500 A
  4. 3 Phase + Neutral +50% & 100% G
  5. Copper & Aluminium conductors
  6. Productive Standard : IEC-61439-6
Medium Voltage
  1. Type: SH, PH, PE
  2. Rated voltage: 7.2kV, 17.5kV, 24kV
  3. Rated Current: 1000 to 5000 A
  4. Productive standard: IEC-62271-201

Core Competency

Core-Competency
- Cast-Resin Busway System
Tecobar-Advantages
  1. Cast-Resin(Junction included)
  2. Certificate(Whole Series)
  3. Fireproof Behavior
  4. Protective Level (IP68 Rated)
  5. Mechanical Impact
  6. Seismic Restraint
  7. Anti-explosive
  8. Compact Dimension
  9. Flexible & Customized
  10. Low EMC
  11. Corrosion Prevention
Cast-Resin (Junction Casted)
Maintenance Free
Long Lifespan: >40 years.
(Aging Test >50 years pasted)
Certificates
Fireproof Behavior
Complied to the standard
IEC 60331: 950℃, 3hrs
Non-combustion, non-combustion-supporting and self-extinguishing
Protection level
IP classification (IEC 60529)

First figure: protection against dust
6 = totally dust free

second figure: protection against water
7 = fully emerged in water (waterproof)
8 = extensively emerged in water
Mechanical impact
IK10=5Kgw*40cm
This indicates the degree of protection against a mechanical load (demand energy in 20 joules) without any crack or indentation.
Seismic restraint
Earthquake protection at 0.8G in tri-axial = Magnitude >7 passed
Explosion Proof
IEC 60079 certified with Ex mb II Gb
Compact dimension
Flexible & tailOr-made
Applicable to all requirements
Panelboard Connection
Core-Competency
- T-LINE LV Distribution Panelboard
Specification
General Data
Standards IEC61439-2, IEC60529
Model TL02 TL04 TL06 TLO8 TL10 TL12
Rated Current (A) 250A 400A 600A 800A 1000A 1200A
Short Circult Rating (kA/415V) 40 40 70 70 80 80
Rated voltage (V) 690
Maln Type 50/60
Frequency (Hz) MCCB TYPE
Main Bus
Model B04 B04 B08 B08 B12 B12
Conductor Material Copper
Insulation Material Epoxy castresin
Insulation Class B CLASS 130°C
Pole Number 12P/24P/36P/48P/60P
Branch MCCB Breaker
Pole 1P/2P/3P
MCCB brands Compatible with all major brands
Enclosure
Type Wall mounted / Floor mounted
Protection Rating IP42 standard, IP55 optional
Color MUNSELL 5Y 7/1
Size (WxHxD) (mm)* 900x2100x400 900x2100x400 1100x2100x400 1100x2100x400 1200x2200x400 1200x2200x400
Welght (without branch breaker) (kg)* 263 265 317 320 380 380
*Standard size with 48P
Why t-line?
Main bus
  • Main bus capacity: max. 1200A.
  • Main bus plug-in slot in pedestal: 12~60P
  • Main bus in one direct capsulation of cast resin with IP21 (IEC60529), and conducting area of plug in slot is covered and insulated to prevent contact of operator and tool.
  • Busway in one capsulation of cast resin, featured in compact structure, safe and fire resistant.
  • Applied advanced cast resin technique to approach reliable re-configuration, safe operation and delicate appearance.
Branch MCCB
  • MCCB Capacity: 15~630AF
  • Compatible to 1-3P
  • Live-line working not to interrupt with other branches in line
  • Connections are “clamping” type to ensure firm gap against high short-circuit
Certificates
The most in needs
  Commercial Industrial O.E.M Utility
T-Line
  • Office Buildings
  • Shopping Malls
  • Retail Stores
  • Super Market
  • Nursing Homes
  • Automotive
  • Pulp & Paper
  • Hospitals
  • All Manufacturing Facilities
  • Panelboard Assemblers
  • HVAC
  • Equipment Rooms
  • Power Generation Facilities
Safety
IP rated
× × × ×
Flexibility
Modify loading
without interruption
× × × ×
Cost Saving
Quick turn around
× × × ×
Simple Maintenance
Easy reconfiguration
× × × ×
For plant production line is NOT ALLOWED to have a power outage at anytime, since power outages will result in:
  1. The production delays, lower production capacity will affecting delivery schedule
  2. The production of products may easily become defective or bad goods, resulting in losses. 
  3. To re-power failure caused by the process equipment to be rectified once again, additional unexpected costs.
  4. The inconvenience of the production management, performance is reduced And so on, will result in a huge loss of overall operating costs.