Core Competency
Core Competency
Core-Competency
- Cast-Resin Busway System
- Cast-Resin Busway System

Tecobar-Advantages
- Cast-Resin(Junction included)
- Certificate(Whole Series)
- Fireproof Behavior
- Protective Level (IP68 Rated)
- Mechanical Impact
- Seismic Restraint
- Anti-explosive
- Compact Dimension
- Flexible & Customized
- Low EMC
- Corrosion Prevention
Cast-Resin (Junction Casted)
Maintenance Free
Long Lifespan: >40 years.
(Aging Test >50 years pasted)
Maintenance Free
Long Lifespan: >40 years.
(Aging Test >50 years pasted)

Certificates

Fireproof Behavior
Complied to the standard
IEC 60331: 950℃, 3hrs
Non-combustion, non-combustion-supporting and self-extinguishing
Complied to the standard
IEC 60331: 950℃, 3hrs
Non-combustion, non-combustion-supporting and self-extinguishing

Protection level
IP classification (IEC 60529)
First figure: protection against dust
6 = totally dust free
second figure: protection against water
7 = fully emerged in water (waterproof)
8 = extensively emerged in water
IP classification (IEC 60529)
First figure: protection against dust
6 = totally dust free
second figure: protection against water
7 = fully emerged in water (waterproof)
8 = extensively emerged in water

Mechanical impact
IK10=5Kgw*40cm
This indicates the degree of protection against a mechanical load (demand energy in 20 joules) without any crack or indentation.
IK10=5Kgw*40cm
This indicates the degree of protection against a mechanical load (demand energy in 20 joules) without any crack or indentation.

Seismic restraint
Earthquake protection at 0.8G in tri-axial = Magnitude >7 passed
Earthquake protection at 0.8G in tri-axial = Magnitude >7 passed

Explosion Proof
IEC 60079 certified with Ex mb II Gb
IEC 60079 certified with Ex mb II Gb

Compact dimension

Flexible & tailOr-made

Applicable to all requirements

Panelboard Connection


Core-Competency
- T-LINE LV Distribution Panelboard
- T-LINE LV Distribution Panelboard

Specification
General Data | ||||||
Standards | IEC61439-2, IEC60529 | |||||
Model | TL02 | TL04 | TL06 | TLO8 | TL10 | TL12 |
Rated Current (A) | 250A | 400A | 600A | 800A | 1000A | 1200A |
Short Circult Rating (kA/415V) | 40 | 40 | 70 | 70 | 80 | 80 |
Rated voltage (V) | 690 | |||||
Maln Type | 50/60 | |||||
Frequency (Hz) | MCCB TYPE | |||||
Main Bus | ||||||
Model | B04 | B04 | B08 | B08 | B12 | B12 |
Conductor Material | Copper | |||||
Insulation Material | Epoxy castresin | |||||
Insulation Class | B CLASS 130°C | |||||
Pole Number | 12P/24P/36P/48P/60P | |||||
Branch MCCB Breaker | ||||||
Pole | 1P/2P/3P | |||||
MCCB brands | Compatible with all major brands | |||||
Enclosure | ||||||
Type | Wall mounted / Floor mounted | |||||
Protection Rating | IP42 standard, IP55 optional | |||||
Color | MUNSELL 5Y 7/1 | |||||
Size (WxHxD) (mm)* | 900x2100x400 | 900x2100x400 | 1100x2100x400 | 1100x2100x400 | 1200x2200x400 | 1200x2200x400 |
Welght (without branch breaker) (kg)* | 263 | 265 | 317 | 320 | 380 | 380 |
Why t-line?

Main bus
- Main bus capacity: max. 1200A.
- Main bus plug-in slot in pedestal: 12~60P
- Main bus in one direct capsulation of cast resin with IP21 (IEC60529), and conducting area of plug in slot is covered and insulated to prevent contact of operator and tool.
- Busway in one capsulation of cast resin, featured in compact structure, safe and fire resistant.
- Applied advanced cast resin technique to approach reliable re-configuration, safe operation and delicate appearance.

Branch MCCB
- MCCB Capacity: 15~630AF
- Compatible to 1-3P
- Live-line working not to interrupt with other branches in line
- Connections are “clamping” type to ensure firm gap against high short-circuit

Certificates

The most in needs
Commercial | Industrial | O.E.M | Utility | |
T-Line |
|
|
|
|
Safety IP rated |
× | × | × | × |
Flexibility Modify loading without interruption |
× | × | × | × |
Cost Saving Quick turn around |
× | × | × | × |
Simple Maintenance Easy reconfiguration |
× | × | × | × |
For plant production line is NOT ALLOWED to have a power outage at anytime, since power outages will result in:
- The production delays, lower production capacity will affecting delivery schedule
- The production of products may easily become defective or bad goods, resulting in losses.
- To re-power failure caused by the process equipment to be rectified once again, additional unexpected costs.
- The inconvenience of the production management, performance is reduced And so on, will result in a huge loss of overall operating costs.